• ISSN 2320-6586 (Online)
  • Monthly since 2013
  • Open access
  • Double blind peer review
editor@ijrmeet.org

Seismic Behavior of Multi-Storey Structures with Shear Wall Systems

  • Kunal HundalIndependent Researcher, India

Keywords:

Seismic behavior, Multi-storey structures, Shear walls, Pushover analysis, Time-history analysis, Drift control, Energy dissipation, Hysteretic modeling, RC shear walls, 2016 design practice

Abstract

This manuscript investigates the seismic behavior of multi-storey reinforced concrete structures incorporating shear wall systems. Emphasis is placed on the influence of shear wall configuration, aspect ratio, opening presence, wall-to-floor area ratio, and interaction with moment frames on dynamic response under earthquake loading. A combination of nonlinear static pushover analyses and time-history analyses is employed to evaluate global performance measures—inter-story drift, base shear, and ductility demand—using representative ground motions recorded in seismic zones up to 2016. Case studies include existing high-rise residential and office buildings retrofitted with shear walls, as well as newly designed structures optimized for seismic resistance. Methodology involves detailed finite element modeling of shear wall–frame interaction, calibration of hysteretic behavior using widely accepted constitutive models, and parametric studies to assess critical design parameters. Results indicate that shear walls significantly enhance lateral stiffness and energy dissipation capacity, reducing inter-story drifts by up to 60 % and base shear demand by 20 % compared to bare frames. However, excessive stiffness concentration can lead to irregular deformation patterns and potential soft-story mechanisms at levels without walls. The study concludes with recommendations on optimal shear wall placement, aspect ratios, and design guidelines consistent with codes as of 2016. Scope and limitations address modeling assumptions, ground motion selection, and generalizability to irregular configurations.

References
American Concrete Institute. (2011). Building Code Requirements for Structural Concrete (ACI 318-11). ACI.
Applied Technology Council. (1996).
ATC-40: Seismic Evaluation and Retrofit of Concrete Buildings. FEMA.
Chakrabarti, A., et al. (2006). Experimental study of coupled shear walls under cyclic lateral loading.
Journal of Structural Engineering, 132(11), 1721–1730.
Comité Européen de Normalisation. (2004).
Eurocode 8: Design of Structures for Earthquake Resistance. CEN.
Federal Emergency Management Agency. (2000).
FEMA 356: Prestandard and Commentary for the Seismic Rehabilitation of Buildings. FEMA.
Federal Emergency Management Agency. (2009).
FEMA P-58: Seismic Performance Assessment of Buildings. FEMA.
Krawinkler, H., & Popov, E. P. (1994). Seismic demands for SDOF and MDOF systems.
Proceedings of the 10th European Conference on Earthquake Engineering, Vienna, Austria.
Park, R., & Paulay, T. (1975).
Reinforced Concrete Structures. Wiley.
Paulay, T., & Priestley, M. J. N. (1992).
Seismic Design of Reinforced Concrete and Masonry Buildings. Wiley.
Scott, B. D., Park, R., & Priestley, M. J. N. (1982). Stress-strain behavior of concrete confined by overlap and spiral reinforcement.
Journal of the American Concrete Institute, 79(1), 13–27.

How to cite

Kunal Hundal (2016). Seismic Behavior of Multi-Storey Structures with Shear Wall Systems. International Journal of Research in Modern Engineering & Emerging Technology, 4(2), 1-5.

Licence

This article is open access, published under the CC BY 4.0 licence. Copyright remains with the authors.

If the issue persists, you can use the old publisher details where you get it published.